NominalEffectiveLineFormulation
- class pmrf.models.components.lines.empirical.NominalEffectiveLineFormulation(*, name: str | None = None, metadata: Any = None)
Bases:
AbstractEffectiveLineFormulationThe RLGC line built directly from the nominal per-unit-length quantities.
This is the default formulation of
EquivalentLineandDatasheetLine, deliberately: CAD “physical” lines, such as ADS/AWRTLINPand scikit-rf’sDefinedAEpTandZ0by default, use a frequency-flat permittivity in the same way. It is not causal. \(G'\) is exactly proportional to \(\omega\) with no Kramers-Kronig partner in \(C'\), and the skin-effect \(R'\) has no matching internal inductance. For a causal line, useGeneralizedEffectiveLineFormulation.Mathematical Formulation
\[Z' = R'_n + j\omega L'_n \qquad Y' = G'_n + j\omega C'_n\]with the nominal quantities of
EffectiveValues. To first order in \(R'/(\omega L')\) and \(G'/(\omega C')\) this isLowLossLine.References
Pozar, D. M. (2011). Microwave Engineering (4th ed.), Sections 2.1 and 2.7. Wiley.
- immittance(freq: Frequency, values: EffectiveValues) ImmittanceResult
Calculate the per-unit-length immittance.
- Parameters:
freq (Frequency) – The frequency axis.
values (EffectiveValues) – The effective values of the line.
- Returns:
The series impedance and shunt admittance.
- Return type: