GeneralizedRCTerm

class pmrf.models.components.lines.empirical.GeneralizedRCTerm(tand: Any, f: Any, *, name: str | None = None, metadata: Any = None)

Bases: Module

A dielectric relaxation term of GeneralizedEffectiveLineFormulation.

A Debye relaxation that adds a loss-tangent peak of height about tand at f, and raises the static capacitance by \(2\tan\delta_i C'_n\), as the Kramers-Kronig relations require.

Mathematical Formulation

\[Y'_i(\omega) = j\omega C'_n \frac{2\tan\delta_i}{1 + j\omega/\omega_i}\]

This is a DebyePole of strength \(\Delta\varepsilon_r = 2\varepsilon_{eff}\tan\delta_i\) at \(f_{relax} = f_i\), normalised by \(\varepsilon_{eff}\).

References

Debye, P. (1929). Polar Molecules. Chemical Catalog Company.

Allen, G. V. C. Precision Circuit Modelling for 21 cm Radiometer Calibration. PhD thesis.

Parameters:
  • tand (Param) – Height of the loss-tangent peak.

  • f (Param) – Relaxation frequency in Hz.

admittance(values: EffectiveValues, omega: Array) → Array

The term’s shunt admittance \(Y'_i\) in S/m.

f: Param

Relaxation frequency

tand: Param