GeneralizedRLTerm

class pmrf.models.components.lines.empirical.GeneralizedRLTerm(A: Any, f: Any, *, name: str | None = None, metadata: Any = None)

Bases: Module

A conductor relaxation term of GeneralizedEffectiveLineFormulation.

A parallel \(R_i \parallel L_i\) in series with the line, which adds conductor attenuation A above f.

Mathematical Formulation

\[Z'_i(\omega) = R_i \frac{j\omega}{\omega_i + j\omega} \qquad R_i = 2 z_n \frac{\ln 10}{20} A_i \qquad L_i = \frac{R_i}{\omega_i}\]

References

Allen, G. V. C. Precision Circuit Modelling for 21 cm Radiometer Calibration. PhD thesis.

Parameters:
  • A (Param) – Extra conductor attenuation in dB/m contributed above f.

  • f (Param) – Corner frequency in Hz.

impedance(values: EffectiveValues, omega: Array) → Array

The term’s series impedance \(Z'_i\) in ohm/m.

A: Param

Extra conductor attenuation in dB/m contributed above f

f: Param

Corner frequency